Subversion Repositories svnkaklik

Compare Revisions

Ignore whitespace Rev 5 → Rev 6

/schemata/prenos/letadlo/vysilac/PCB/VYSILAC.DRC
0,0 → 1,83
 
Checking Pins and Pin Connections
 
--------------------------------------------------
Checking Schematic: SCHEMATIC1
--------------------------------------------------
Checking Electrical Rules
ERROR: [DRC0004] Possible pin type conflict J7,3 Output Connected to Power
SCHEMATIC1, PAGE1 (22.86, 48.26)
ERROR: [DRC0004] Possible pin type conflict U1,VSS Power Connected to Output
SCHEMATIC1, PAGE1 (165.10, 121.92)
ERROR: [DRC0004] Possible pin type conflict U4,K Power Connected to Output
SCHEMATIC1, PAGE1 (187.96, 78.74)
WARNING: [DRC0004] Possible pin type conflict U4,Ref. Output Connected to Bidirectional
SCHEMATIC1, PAGE1 (170.18, 78.74)
ERROR: [DRC0004] Possible pin type conflict J7,2 Output Connected to Power
SCHEMATIC1, PAGE1 (22.86, 50.80)
 
Checking for Unconnected Nets
WARNING: [DRC0007] Net has no driving source N68779
SCHEMATIC1, PAGE1 (91.44, 109.22)
WARNING: [DRC0007] Net has no driving source N58442
SCHEMATIC1, PAGE1 (231.14, 45.72)
WARNING: [DRC0006] Net has fewer than two connections N68779
SCHEMATIC1, PAGE1 (91.44, 109.22)
WARNING: [DRC0006] Net has fewer than two connections N58442
SCHEMATIC1, PAGE1 (231.14, 45.72)
ERROR: [DRC0029] Bus has no name and therefore defines no signals. N30740
SCHEMATIC1, PAGE1 (68.58, 35.56)
ERROR: [DRC0029] Bus has no name and therefore defines no signals. N46090
SCHEMATIC1, PAGE1 (231.14, 45.72)
 
Checking for Invalid References
 
Checking for Duplicate References
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (231.14, 45.72)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (231.14, 40.64)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N58442
SCHEMATIC1, PAGE1 (231.14, 45.72)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N58442
SCHEMATIC1, PAGE1 (231.14, 45.72)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N58442
SCHEMATIC1, PAGE1 (231.14, 43.18)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N58442
SCHEMATIC1, PAGE1 (231.14, 43.18)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (231.14, 43.18)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (231.14, 43.18)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (231.14, 45.72)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N58442
SCHEMATIC1, PAGE1 (231.14, 43.18)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N58442
SCHEMATIC1, PAGE1 (231.14, 43.18)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N58442
SCHEMATIC1, PAGE1 (231.14, 40.64)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N58442
SCHEMATIC1, PAGE1 (231.14, 40.64)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (231.14, 40.64)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (231.14, 43.18)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (231.14, 43.18)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (91.44, 109.22)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (91.44, 111.76)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N68779
SCHEMATIC1, PAGE1 (91.44, 109.22)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N68779
SCHEMATIC1, PAGE1 (91.44, 109.22)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N68779
SCHEMATIC1, PAGE1 (91.44, 111.76)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N68779
SCHEMATIC1, PAGE1 (91.44, 111.76)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (91.44, 111.76)
WARNING: [DRC0034] Two wires/busses of different nets intersect visually, yet nets are not connected N46090
SCHEMATIC1, PAGE1 (91.44, 109.22)